Once all of the utilities were roughed in, it was time to
finally get insulation. This is a topic that’s high on my list of priorities
and I could spend several blogs harping about insulation, but I won’t… too much.
:P
I do get excited about R-values, infiltration rates,
cellulose vs. fiberglass (I can see Shawn’s eyes are rolling already) I admit
it: I can be weird. And here’s where I got weird. I wanted to spend more on
insulation than on granite countertops. I have been pickier about what goes in
behind the drywall than what will come after it; well, maybe I’ve been obsessed
with insulation more than picky. What did Shawn say? Paranoid about insulation?
Yeah, that could describe the level of weirdness on my obsession.
Our contractor’s insulation bid was the normal blown in
fiberglass in the walls with fiberglass in the attic. But I adamantly refused,
knowing full well that what I want will cost 3 times what he bid. But really?
How often do you upgrade insulation? My argument is I can upgrade countertops,
paint, fixtures, and all sorts of things if we have to, but not insulation. I
will readily admit I went overboard, but I hate being cold (must be that
Honduran still in me), so the more there is between me and the exterior cold,
the better. We ended up going with spray from insulation, and did a hybrid
thing.
First a skim coat of heavy dense 2lb foam in the wall cavities. This is
mainly to provide air sealing since a lot of the heat lost in a house is due to
infiltration. Also, this type of foam is more expensive so could only afford a
little of it. That gave us an R7.4. That’s the blue foam you can see inside the
wall cavity.
Next, the rest of the wall cavity was filled full of the
lighter spray foam, then shaved flush at the studs. Add another R16 to the
walls. And since we have a 1” of foam board on exterior of wall, we now have a
total of R30 in our walls!
The guy in the picture above is Dane, our insulation sub, cutting the lighter foam (cream
colored one) flush after he sprayed the walls. He is the same sub that we used
3 years ago to spray foam all around the rim joist before we moved into the
basement. And here he is spraying our vaulted ceiling full of R50 foam.
| Not sure OSHA would approve |
To help some of the infiltration, Shawn and I went around
and caulked the joint between the bottom plate of all exterior walls and the
subfloor. Caulked the butt joint between the two top plates on top of the exterior
walls, and wherever there were two or more studs butted together, we caulked
that joint.
| Doesn't that look cozy already? |
This was something the contractor said they like to do on their
houses, and it sounded like a good idea to me (Shawn probably thought more
overkill).
You can see in this picture all of the white along the floor
and at every butt joint of wood.
We couldn’t afford to do a skim coat of the blue spray foam
in the attic on top of the sheetrock to seal air infiltration there. So the
next best thing was that we went around with a can of foam insulation and
sealed every hole through the top plates of all the interior walls into the
attic. And tons of holes there were.
| It didn't really take all that long to take care of this. |
You can see in this picture where the
arrow points to the foam sealing where the electric wires make their way into
the attic. I did that around every plumbing pipe too.
The insulation in the attic will slow down this heat
transfer between hot room and cold attic, but it won’t do much air leaking in
and out, specially Fiberglass loose blown in the attic. But you can google
that. I’ll just leave it at controlling air infiltration is as important as how
much insulation you have in your attic. So instead of fiberglass, I wanted
cellulose. Not just any cellulose of course. I want sulfur-free cellulose (or
it will smell like a rotten egg when humid) and I wanted a lot of it. R50
total, which is about 15” of cellulose.
Speaking of attic insulation, because our trusses don’t have
an energy heel on them, the most cellulose we would get right on top of
exterior walls would be 6” of it, which is about R13. Right here is a spot
where more insulation would have been better, because it is the shortest path
for heat from interior to exterior (and heat, like water, likes the path of
least resistance to go to cold). Imagine this part of the roof full of snow in
the middle of winter. R13 here will practically be ice dam city all winter
long.
| Filling up energy heel with foam. |
So I asked to spend premium dollars to fill this whole thing
with the blue spray foam to maximize Rvalue. This got us closer to R40, which
is good.
New international residency code calls for R50 minimum in
the attic for my area and climate, though local codes are still only requiring
R38 min (not enough).
The other thing that needed to be air sealed is wherever
there is a light or can light in the ceiling. If you look at a house, the
ceiling ends up being like a Swiss cheese with all of those holes cut into the
drywall wherever there is a light box. Because of the stack effect, where hot
air rises and creates a pressure difference between the hot warm interior and
the cold attic, you literally get like a vacuum effect that causes enough heat
to be lost through the ceiling. The cumulative effect of all those ceiling
fixture holes is like having an open window with the heat running.
But, to seal these holes in the ceiling, first we needed to
have drywall! So yes, drywall came next.
Quickly we discovered that it really wasn’t saving us much
money to not drywall the garage since we would not get the drywall guys to come
back and do that later for what they would charge to do it now when they were
here. But we also wanted to insulate the garage, and of course no money left in
the budget to pay someone to do it (since I did spend all of it on fancy
insulation as Shawn calls it… and a Beam vacuum).
| See, I knew that was worth saving! |
Remember that pile of insulation that we saved and hauled up
to the barn loft? Yeap. It had to come down since it was now going to become
our new garage insulation.
| This stuff super itchy. |
So we took vacation off work one day and went to
work. Again, fully decked out in tyvek suits and masks, we got the garage
insulated and ready for drywall.
Here's a shot of our garage after we got done insulating it.
| Should be able to keep some heat in here now! |
| Say Cheese! |
While we were working on the garage insulation, the
fireplace sub showed up to finish installing the chimney cap and spark
arrestors on our chimneys. So I snapped a couple of pictures while they worked.
Inside, we also needed to take care of a few things to get
ready for drywall. We went around and sealed with foam around all of the
windows (again that insulation and infiltration stuff) then stuffed the rest of
that cavity with fiberglass.
| 101 Uses of Whinny combs! |
We also had to have the insulator come back to
scrape the walls some more since the spray foam insulation was sticking out
past the studs and it would cause the drywall to bulge out.
And then we
nitpicked that too so we used a horse curry comb to scrape the foam some more.
That’s what Shawn is doing in this picture.
| Soundproofed. |
Another thing that needed to get done before drywall was
sound wall insulation. This is to help minimize noise between walls of a
bathroom and bedroom, mainly for privacy reasons. So Shawn and I did that too. Here you can see him here in the bedroom wall.
Then finally it was time for the drywall crew to come. And
they came and they went fast! This is my favorite milestone in construction.
The interior finally takes shape, and from now on it’s the pretty stuff that
happens.
| Next, it needs some paint |
First thing to get drywalled was the garage. What a difference!
Here's another view of the drywalled garage where the new landing is. Unfortunately we won't be able to afford to pay someone to prime and paint the garage, so that will fall on us to do, but we'll wait until it warms up a little.
| We like the door moved here better! |
After hanging the drywall, they taped and mudded the joints
and did the texture. Here’s where we had a huge problem. I don’t think our
contractor grasped how seriously tight our house is. Yes… all my fault because
of my fancy insulation/air sealing job. Good for later when we want to keep air
from escaping. Not good now because all of that moisture from the taping and
mudding had nowhere to go. Here's some shots of drywall!
| View from mudroom through new opened up wall! |
| From kitchen looking towards foyer and stairs |
| The new vaulted ceiling |
| The dehumidifier did the trick. |
Our geo unit was not yet running (mainly because I did not
want them to install it during drywall stage since all of that dust would go
straight into the blower and we ain’t about to pay tens of thousands of dollars
to get that thing clogged up with drywall). So the water was literally running
down the windows where it was condensing because of the cold outside. We had
pools of water on the floor. Shawn and I dug out the dehumidifier, pulled out
every fan we owned and got to work.
The contractor also wanted heat in there to help the drywall
mud cure, so we dug up our handy ventless propane heater that we bought several
years ago when the one and only heater in the old house died in the middle of
one winter. (Did I mention that all of these items were the first to get packed
into the storage room?) I thought I’d snapped a picture of our heater, but
didn’t.
Shawn hooked up the heater to the propane line for the
kitchen cooktop, and it did a nice job of keeping the house at 65-70 in the
main floor, despite the fact that there was no insulation in the attic yet.
We also cranked up the basement radiant heat to like 85. I
think the crews were ready to strip down to their underwear to work since it
did get hot. J
Soon, in a day the dehumidifier did its job and the moisture
went away. We did end up with some damage to a couple of pieces on the windows
that would need to be replaced. But other than that, things are good.
Now that we had drywall in the ceiling, it was time for me to
crawl up in the attic and satisfy my obsession with air sealing. So I crawled
around on my hands and knees trying very carefully not to put my foot through
the ceiling drywall. We mostly worked during the evenings, so the nice thing
was that I could shut off the flash light and if I could see light from the
main floor through a can light or light box, it got globbed with foam to seal
it. So now I can sleep better knowing I gave it my best shot. After the attic
sealing job was done, Dane came back to fill our attic full of cellulose.
We did get our first real snow accumulation right before
Christmas, so Shawn fired up our lawn tractor and snowblower to clear the lane
out because drywallers were still working. I headed to town to get some fuel
for the lawn mower, and I came within a hair of blowing me along with the kids
up. Thank God we didn’t end up burned up or blown up to pieces. It was scary at
the time… still is thinking that one spark and we were gonners. I was done
filling up the gas can, so then added gas to the car. It was freezing outside
so I didn’t want to wait to fill it up completely, so I squeezed the handle to
stop it and the lock came undone, but when I pulled out the nozzle it was still
on! I’m squeezing the trigger, but the stupid thing is broken and won’t shut
off. The nozzle was stuck open and I’m just standing there holding this spewing
thing aiming it away from us. So fuel is pouring everywhere onto the ground and
I didn’t know what to do. I’m frantically scanning for the emergency
shut off and I can’t see it anywhere on the building (and I’m afraid to move in
case static electricity sparked or something) and I’m yelling at the teenager
at the register who is texting. I’m about to throw the nozzle on the ground to
go in and choke her, when she finally looks up, freezes just staring at me,
while I’m waving my hand and making the kill-throat motion. I’m sure I meant it
as shut off the thing, not the you’re dead thing. I’m sure it didn’t take her
long, but it seemed like she stared for a long time. Finally she pushed the
darn button to shut off the valve. I wasn’t sure if I should turn on the car or
not, but eventually I drive away, reeking of gas since some splattered all over
my shoes. I look at the rearview mirror and both kids are sound asleep. Thank
you Lord because nothing bad happened.
All the way home I’m going over things trying to think what
I could have done differently. I am more cautious now and look at the pump
first to see the fuel is indeed shut off before I pull the nozzle out, since
the safety warning on the pump (yeah, I took the time to read it now) says
don’t pull it out if that happens!
When I got back, I snapped a picture of Shawn blowing out the lane.
Back to construction: One last thing to highlight this post
is that while insulation and drywall was going on inside, the exterior stone
work was going on outside. Since it was December and cold, they covered the
porch with plastic and use portable heaters to help. They can stone/grout ok
down to 30 degree weather.
| Next step, finish siding and get some columns. |
So now the bottom of the exterior columns are built and stoned as
well as the porch and the area in front of the garage. There was only one
miscommunication about the water ledge that I wanted on top of the stone on the
garage walls. But it wasn’t a big deal and they re-did it. The color of the
stone has a lot of the colors that we have in our shingles. It also goes well
with the retaining blocks that we used on our window wells around the corner
and we like how it goes with our siding color.
Next came the coat of primer. And the holidays. Not much really happened during the Christmas holiday
construction-wise, but right after the new year the trim carpenters will start!
Hope everyone had a Merry Christmas!
Hope everyone had a Merry Christmas!
So that’s it for this month. Next month: Trim!